Prior to preliminary concentration testing, the elicitors were added to the media at day 0 and standardized to a concentration of 0.2 mg per 25 mL. The stock solutions of each substance were sterilized by filtration (0.22 µm). The experiment was made up of triplicates of every treatment (LG, IN, MCoA and IS) and control (no treatment). Samples from each triplicate flask with and without treatments were harvested after Inhibitors,research,lifescience,medical 2, 24, 48, 96, 144, 192, 240 and 288 h for the determination of fresh and
dry weight, pH, conductivity, phenolic compounds (phenolic acids, anthocyanin) after stimulation and also from pool (0 h). 3.6. Estimation of Experimental Parameters from Plant Cells and Medium The following parameters were GSK J4 research buy measured from each sample; pH, conductivity, fresh and dry
weight and phenolic compounds. The pH meter (CG811; Schott Geräte GmbH, Hofheim, Germany) and conductivity meter (WTW LF 323; Weilheim, Germany) were used to estimate the pH and conductivity of metabolic end products and the nutrient Inhibitors,research,lifescience,medical contents in the medium. The pH and conductivity of every sample were measured within a time lapse of 30 s to stabilize both parameters at room temperature. The plant cells were filtered Inhibitors,research,lifescience,medical using suction filter (SARSTEDT, Germany) in a vacuum for one minute followed by weighting. One-gram of fresh plant material was dried in a prepared aluminum box and kept at 105 °C in an oven for 24 h. After the drying process, the samples were transferred for one hour in to an exsiccator. Thereafter, the dry weights were measured and the water content was calculated. Plant cells of V. vinifera were harvested using vacuum Inhibitors,research,lifescience,medical filtration flask. At each day of harvest, the fresh and dry weights, pH and conductivity were estimated and the chemical components were analyzed. The harvested plant cells for the phenolic acid
extraction were immediately flash frozen in liquid nitrogen and transferred for the freeze-drying process (lyophilization). 3.7. Chemical Analysis of Phenolic Acids with HPLC For chemical analysis, about 40 mg powdered callus samples (freeze-dried) were extracted within 15min using Inhibitors,research,lifescience,medical 750 µL of 70% methanol (v/v; pH 4; 0.1% phosphoric acid) containing 40 µL of the internal standard p-coumaric acid (3 mmol) in an iced ultrasonic water bath. All samples were centrifuged at 4,500 rpm (2,150 × g) and 4 °C for 5 min. The supernatants were collected in new tubes and the pellets were re-extracted with 500 µL of 70% methanol (twice). After Methisazone extraction, aliquots of the samples were collected and the solvent was completely removed using a rotary evaporator (Speed Vac, SC 110) under vacuum at room temperature (25 °C). The residues were filtered using centrifuge tubes (SpinX) and the extracts were dissolved with 40% acetonitrile to reach the 1 mL mark. The chromatography was performed using a Dionex Summit P680A HPLC system with an ASI-100 auto sampler and a PDA-100 photodiode array detector.